next up previous contents
Next: Results Up: NH - NO (- Previous: Reaction Mechanisms

Induction Time Data

Data from [Soloukhin (1971)] are difficult to reproduce numerically because the experimental conditions are not clear. Initial pressures are only hinted at and initial concentrations are unclear. The NH3-N2O mixtures are said to be stoichiometric, but the meaning of ``stoichiometric'' is unclear because example figures suggest equimolar mixtures were used.


Joe E. Shepherd
2000-01-17